| Step | Action | |
|---|---|---|
| 1 | Install the filer in the equipment rack or system cabinet, as described in the appropriate hardware and service guide. | |
| 2 | Install the disk shelves, as described in the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide. | |
| 3 | Check the Media Kit that came with the system and compare it to the version of Data ONTAP installed on the FAS250. | |
| 4 | Check the motherboard firmware level and update it, if needed. | |
| 5
|
If the Data ONTAP version is... |
Then... |
| The same revision level or later | Go to Step 6. | |
| An earlier revision level |
tar xvf /mnt/ filenameinstall_netapp . Note: In a Windows® environment, you must unzip the files and run setup.exe. See the Software Setup Guide for more information.
download
|
|
| 6 | Go to Updating Data ONTAP on the FAS250. | |
You might need to update Data ONTAP on the FAS250 to match the revision level of the F825 or FAS900 before changing any hardware on the system. Both the FAS250 and the F825/F900 must be running the same version of Data ONTAP.
To update Data ONTAP on the FAS250, complete the following steps.
| Step | Action | |
|---|---|---|
| 1 | Check the Media Kit that came with the modular system packaging for the version of Data ONTAP installed on the FAS900. | |
| 2
|
If the Data ONTAP version is... |
Then... |
| The same revision level or later | Go to Step 3. | |
| An earlier revision level |
tar xvf /mnt/ filenameinstall_netapp . Note: In a Windows environment, you must unzip the files and run setup.exe. See the Software Setup Guide for more information. Caution: Do not reboot the FAS250.
download |
|
| 3 | Reboot the system by entering the following
command:
reboot |
|
| 4 |
Enter the following command at the FAS250 console: halt | |
| 5 | Turn off the power and disconnect the system from the power source, then remove the cabling from the system. | |
| 6 | Go to Converting the hardware. | |
To convert the FAS250 hardware, complete the following steps, using the illustrations for reference.


| Step | Action | |
|---|---|---|
| 1 | While grounded, remove the CPU module and blank filer module from the back of the FAS250. | |
| 2 |
Insert the LRC/ESH modules into the FAS250, with the bottom LRC/ESH right side up and the top LRC/ESH module upside down. Note: The LRC/ESH modules are keyed and can only be inserted one way. |
|
| 3
|
If the last disk shelf has... |
Then... |
| LRCs | Set the converted FAS250 disk shelf loop speed to 1 Gb. | |
| ESHs | Set the converted FAS250 disk shelf loop speed to the same setting as the last disk shelf on the FAS900. | |
| 4 | Replace the bezel by completing the steps in the bezel replacement kit flyer. | |
| 5 | Go to Completing the upgrade. | |
Completing the upgrade is a two-step process:
To complete the upgrade by installing the converted FAS250, complete the following steps.
| Step | Action | |
|---|---|---|
| 1 |
Cable the FAS250, set the disk shelf ID, and set the terminate switches, as described in the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide. |
|
| 2 |
Reconnect the system to the power source, power on the disk shelves, and then power on the filer and complete the setup script, if needed. |
|
| 3 |
Check the volume status by entering the following command: vol status Note: The volumes on the converted FAS250 are displayed as offline. The root volume is displayed as vol0(1), if you use the default volume names. Your root volume might be named differently. |
|
| 4 |
Rename the root volume on the FAS900 disk shelf to old_vol0, by entering the following command: vol rename vol0 old_vol0 |
|
|
5 |
Rename the FAS250 root volume to vol0 by completing the following procedure:
vol online vol0(1)
vol rename vol0(1) vol1vol rename vol1 vol0 |
|
|
6 |
Set the renamed volume from the FAS250 to the root volume by entering the following command: vol options vol0 root |
|
|
7 |
Reboot the system by entering the following command from the console: reboot |
|
|
8 |
The MIPS binaries still reside in the root volume of the converted FAS250. You must download and install the FAS900 version of Data ONTAP to get the correct binaries on the disks. Install Data ONTAP by completing the following steps:
tar xvf /mnt/ filename
install_netapp . Note: In a Windows environment, you must unzip the files and run setup.exe . |
|
| 9 |
Download the image to the CompactFlash card by entering the following command: download |
|
| 10 |
Reboot the system. |
|
| 11 |
If the data in the old root volume is not needed, you can remove it. |
|
The following procedure assumes that you are taking the FAS250 completely out of service and returning it to Network Appliance.
To complete the decommissioning process, complete the following steps.
| Step | Action |
|---|---|
| 1 |
Go to the NOW Web site at http://now.netapp.com/. |
| 2 |
Search for Decommission this System and follow the instructions. |
| 3 |
Return the FAS250 modules to Network Appliance, as described in the SRA instructions shipped with the conversion kit. Contact Customer Support, at 408-822-6686, if you need the SRA instructions. |
Part Number: 215-00744
Last updated: November 20, 2003